fix: circuit breaker deadlock — always query sidecar for status
The circuit breaker opened after MAX_RECOVERY_ATTEMPTS failures but was never reset because the sidecar status query (which calls circuit_reset()) was skipped when the circuit was open. This caused a permanent deadlock: all subsequent requests went to the LXC fallback with no recovery possible. Fix: always query the sidecar for /models/status, even when the circuit is open. If the sidecar responds successfully, reset the circuit. The circuit breaker now only prevents the SWITCH operation, not the status health check. If a model is already running when the circuit is open, route to it directly.
This commit is contained in:
parent
bcf45129f1
commit
7e9b3f43e1
17
main.py
17
main.py
@ -403,12 +403,7 @@ async def proxy(
|
|||||||
error: Optional[str] = None
|
error: Optional[str] = None
|
||||||
sidecar_status = None
|
sidecar_status = None
|
||||||
|
|
||||||
# Circuit breaker check
|
# Always query the sidecar first (to detect recovery even when circuit is open)
|
||||||
if not await circuit_breaker_check():
|
|
||||||
error = "circuit_open"
|
|
||||||
else:
|
|
||||||
# Query Sidecar for active model
|
|
||||||
sidecar_status = None
|
|
||||||
async with httpx.AsyncClient(timeout=3.0) as client:
|
async with httpx.AsyncClient(timeout=3.0) as client:
|
||||||
try:
|
try:
|
||||||
resp = await client.get(f"{SIDECAR_URL}/models/status")
|
resp = await client.get(f"{SIDECAR_URL}/models/status")
|
||||||
@ -416,13 +411,19 @@ async def proxy(
|
|||||||
sidecar_status = resp.json()
|
sidecar_status = resp.json()
|
||||||
circuit_reset()
|
circuit_reset()
|
||||||
except Exception:
|
except Exception:
|
||||||
error = "sidecar_down"
|
pass # Handled below
|
||||||
|
|
||||||
if sidecar_status is None:
|
if sidecar_status is None:
|
||||||
circuit_record_failure()
|
circuit_record_failure()
|
||||||
error = "sidecar_down"
|
error = "sidecar_down"
|
||||||
|
elif not await circuit_breaker_check():
|
||||||
|
# Sidecar is up but circuit is open from prior switch failures
|
||||||
|
# Only block the switch — allow routing to already-active backend
|
||||||
|
error = "circuit_open"
|
||||||
|
if sidecar_status.get("llama_server_running"):
|
||||||
|
target_url = f"{MAIN_PC_BASE}/{path}"
|
||||||
else:
|
else:
|
||||||
# Extract requested model from request body
|
# Both sidecar reachable and circuit closed — proceed normally
|
||||||
body = await request.body()
|
body = await request.body()
|
||||||
body_data = json.loads(body) if body else {}
|
body_data = json.loads(body) if body else {}
|
||||||
requested_model = body_data.get("model")
|
requested_model = body_data.get("model")
|
||||||
|
|||||||